Upon completion there must be no cut, or stray
strands of wire present and the cable clamp must
be secure over the outer sheath.
A cut off plug inserted into a 13 amp
socket is a serious safety (shock)
hazard. Ensure that the cut off plug is
disposed of safely.
Permanent Connection
In the case of a permanent connection, it is
necessary that you install a double pole switch
between the hob and the electricity supply
(mains), with a minimum gap of 3 mm. between
the switch contacts and of a type suitable for
the required load in compliance with the current
electric regulations.
The switch must not break the yellow and green
earth cable at any point.
Ensure that the hob supply cable does
not come into contact with surfaces
with temperatures higher than 50 deg.
C.
Supply cable replacement
The cable used to connect the hob to the
electrical supply must comply to the
specifications given below.
Min. size Cable/flex
2
0.75 mm
Cable / flex type
H05 V2V2-F (T90)
Fuse
3 A