Symptom
Paper is not fed (pick error
occurs frequently, or docu-
ment stops midway).
The generated images are
elongated.
There is a shadow on the
leading edge of the gener-
ated image?
AP-2
Check this item
Do the documents satisfy the "Docu-
ment Quality" and the "Multi feed
Detection Conditions" in the chapter 6
of the fi-5530C Operator's Guide?
Is the Pick roller dirty?
Is the Pick roller worn out?
Is there any debris on the document feed
path?
Are the Feed rollers dirty?
Have you adjusted the scan scale?
Are the Feed rollers dirty?
Have you adjusted the offset (the scan-
ning starting position)?
Remedy
Use the documents that satisfy the "Document
Quality" and the "Multi feed Detection Condi-
tions" in the chapter 6 of the fi-5530C Operator's
Guide.
Clean the Pick roller. Refer to the Operator's
Guide "3.2. Cleaning the ADF".
Clean the Pick roller. Refer to the Operator's
Guide "4.3. Replacing the Pick Roller".
Remove any debris from the document feed path.
Clean the Feed rollers. Refer to the Operator's
Guide "3.2. Cleaning the ADF".
For Windows 98, Windows Me, Windows 2000,
WindowsXP, select "Scanners and Cameras" in
the control panel, then click the [Device Set] tab
to adjust scale.
For Windows 95, Windows NT 4.0, right click the
Scanner Control Center in the task tray, select
[Options] and adjust the scan scale.
Clean the Feed rollers. Refer to the Operator's
Guide "3.2. Cleaning the ADF".
For Windows 98, Windows Me, Windows 2000,
WindowsXP, adjust the [Sub-scan Setting] on
[Scanners and Cameras] in the control panel.
For Windows 95, Windows NT 4.0, right click the
Scanner Control Center, select [Options]-[Sub-
scan Setting] and adjust the offset.