- ページ 12

ストレージ Fujitsu ETERNUS DX DiskのPDF 設定マニュアルをオンラインで閲覧またはダウンロードできます。Fujitsu ETERNUS DX Disk 43 ページ。 Server connection, fcoe for linux driver settings for converged network adapter cards
Fujitsu ETERNUS DX Disk にも: ユーザーマニュアル (35 ページ), ユーザーマニュアル (42 ページ), 設定マニュアル (28 ページ), 設定マニュアル (44 ページ), 設定マニュアル (28 ページ), 設定マニュアル (29 ページ), 設定マニュアル (25 ページ), 設定マニュアル (32 ページ), 設定マニュアル (35 ページ), 設定マニュアル (31 ページ), 設定マニュアル (21 ページ), 設定マニュアル (24 ページ)

Fujitsu ETERNUS DX Disk 設定マニュアル
Chapter 3
Notes
3.4

HP Serviceguard Notes

3.4
HP Serviceguard Notes
"HP Serviceguard" is HP-UX cluster software. For details on how to configure an HP Serviceguard system, refer
to the relevant HP-UX manual.
3.5

HP Integrity VM Notes

Apply the settings described in this manual for a VM Host, which is an OS for operating Integrity VM.
3.6

Veritas Volume Manager (VxVM) Notes

Confirm and acquire the ASL required for using the ETERNUS AF/DX storage systems from the following Ver-
itas web-site.
https://sort.veritas.com/asl
Install Veritas Array Support Library (ASL) after installing VxVM.
For VxVM 5.1 or later
ASL does not need to be installed.
3.7
Notes for Veritas Volume Manager Dynamic Multipathing
(VxVM DMP)
When using the VxVM DMP function, do not use it with a single path configuration.
3.8

Veritas Cluster Server (VCS) Notes

Veritas Cluster Server should be installed according to the directions given in the documentation provided
with Veritas Cluster Server.
3.9

Server Startup and Power Supply Control Notes

Before turning the server on, check that the ETERNUS AF/DX storage systems and Fibre Channel switches are
all "Ready". If the server is turned on and they are not "Ready", the server will not be able to recognize the
ETERNUS AF/DX storage systems.
Also, when the ETERNUS AF/DX power supply is being controlled by a connected server, make sure that the
ETERNUS AF/DX does not shut down before the connected servers. Similarly, the Fibre Channel switches must
also be turned off after the connected servers have been shut down. If turned off, data writes from the run-
ning server cannot be saved to the ETERNUS AF/DX storage systems, and already saved data may also be
affected.
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX
12
Copyright 2020 FUJITSU LIMITED
P3AM-3772-22ENZ0