- ページ 7
換気フード AEG 825 DのPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。AEG 825 D 20 ページ。 Cooker hood
AEG 825 D にも: 据付・取扱説明書 (19 ページ), 操作およびインストール手順 (19 ページ)
Installation
Safety warnings for kitchen unit installer
When used as an extractor unit, the hood must be fitted with a
120mm diameter hose.
If the fumes must be forced out through the wall, you must obtain
a MKZ sizable wall exhaust pipe (with external exhaust and air
intake), E-Nr.- 610 899 004 (Ø 120 mm) which is one of our
optional parts.
When installing the hood, make sure you respect the follow-
ing minimum distance from the top edge of the cooking
hob/ring surfaces:
Electric hob
Gas hob
Electric cooker
Gas cooker
The cooker hood must not be installed above a cooker with a
high level grill.
The air outlet must not be connected to chimney flues or combus-
tion gas ducts. The air outlet must under no circumstances be
connected to ventilation ducts for rooms in which fuel-burning
appliances are installed.
It is advisable to apply for authorization from the relevant
controlling authority when connecting the outlet to an unused
chimney flue or combustion gas duct.
The air outlet installation must comply with the regulations laid
down by the relevant authorities.
When the unit is used in its extractor version, a sufficiently large
ventilation hole must be provided, with dimensions that are
approximately the same as the outlet hole.
National and regional building regulations impose a number of
restrictions on using hoods and fuel-burning appliances connected
to a chimney, such as coal or oil room-heaters and gas fires, in the
same room.
600 mm
650 mm
685 mm
787 mm
7