- ページ 8

換気フード AEG 8359 DのPDF 据付・取扱説明書をオンラインで閲覧またはダウンロードできます。AEG 8359 D 18 ページ。 Fume extractor hood

Installation

Safety warnings for kitchen unit installer

When used as an extractor unit, the hood must be fitted with
a 150mm diameter hose.
If the fumes must be forced out through the wall, you must
obtain a MKZ sizable wall exhaust pipe (with external
exhaust and air intake), E-Nr.- 942 118 609 (Ø 150 mm)
which is one of our optional parts.
When installing the hood, make sure you respect the
following minimum distance from the top edge of the
cooking hob/ring surfaces:
electric cookers
gas cookers
coal and oil cookers
The air outlet must not be connected to chimney flues or
combustion gas ducts. The air outlet must under no circum-
stances be connected to ventilation ducts for rooms in which
fuel-burning appliances are installed.
It is advisable to apply for authorization from the relevant
controlling authority when connecting the outlet to an unused
chimney flue or combustion gas duct.
The air outlet installation must comply with the regulations
laid down by the relevant authorities.
When the unit is used in its extractor version, a sufficiently
large ventilation hole must be provided, with dimensions that
are approximately the same as the outlet hole.
National and regional building regulations impose a number
of restrictions on using hoods and fuel-burning appliances
connected to a chimney, such as coal or oil room-heaters
and gas fires, in the same room.
The national decree on fuel-burning systems specifies a
maximum depression of 0.04 bar in such rooms.
Hoods can only be used safely with appliances connected to
24
600 mm
650 mm
700 mm min.