- ページ 16

ポータブル発電機 Kohler 20RESCのPDF オペレーションをオンラインで閲覧またはダウンロードできます。Kohler 20RESC 20 ページ。 Residential/commercial generator sets
Kohler 20RESC にも: インストレーション・インストラクション (2 ページ), 据付・取扱説明書 (37 ページ)

Kohler 20RESC オペレーション
RDC2 Controller Features
Six-button keypad
D
OFF, AUTO, and RUN pushbuttons
d
Select and arrow buttons for access to system
d
configuration and adjustment menus
LED indicators for OFF, AUTO, and RUN modes
D
LED indicators for utility power and generator set
D
source availability and ATS position (Model RXT
transfer switch required)
LCD display
D
Two lines x 16 characters per line
d
Backlit display with adjustable contrast for
d
excellent visibility in all lighting conditions
Scrolling system status display
D
Generator set status
d
Voltage and frequency
d
Engine temperature
d
Oil pressure
d
Battery voltage
d
Engine runtime hours
d
Date and time displays
D
Smart engine cooldown senses engine temperature
D
Digital
isochronous
D
steady-state speed at all loads
Digital voltage regulation: ±0.5% RMS no-load to
D
full-load
Automatic start with programmed cranking cycle
D
Programmable exerciser can be set to start
D
automatically on any future day and time, and run
every week or every two weeks
Exercise modes
D
Unloaded weekly exercise with complete system
d
diagnostics
Unloaded full-speed exercise
d
Loaded full-speed exercise (Model RXT ATS
d
required)
Front-access mini USB connector for Kohlerr
D
SiteTecht connection
Integral Ethernet connector for the Kohlerr OnCuer
D
Plus Generator Management System
16
Section 1 Descriptions and Service Views
governor
to
maintain
Built-in battery charger
D
Remote two-wire start/stop capability for connection
D
of Model RDT or other transfer switches
Diagnostic messages
D
Displays diagnostic messages for the engine,
d
generator, Model RXT transfer switch,
programmable interface module (PIM), and load
management device
Over 70 diagnostic messages can be displayed
d
Maintenance reminders
D
System settings
D
System voltage, frequency, and phase
d
Voltage adjustment
d
Measurement system, English or metric
d
ATS status (Model RXT ATS required)
D
Source availability
d
ATS position (normal/utility or
d
emergency/generator)
Source voltage and frequency
d
ATS control (Model RXT ATS required)
D
Source voltage and frequency settings
d
Engine start time delay
d
Transfer time delays
d
Voltage calibration
d
Fixed pickup and dropout settings
d
Programmable Interface Module (PIM) status
D
displays
Input status (active/inactive)
d
Output status (active/inactive)
d
Load control menus
D
Load status
d
Test function
d
TP-6804 6/15