セキュリティシステム AVS Electronics VECTOR PlusのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。AVS Electronics VECTOR Plus 12 ページ。 Bidirectional gsm interface

Other display indications

As stated before, at power up an initialization procedure of about 1 minute takes place, during
which the equipment configures itself according to programming parameters stored in the SIM
card. The 7-segments display shows some default characters to indicate the advancement of
this process:
at the beginning, a line shifts on the display from bottom to top. Then an A character flashes
for about 30 - 40 seconds. Finally, a C character shows till the end of the initialization, when the
led bar will start to indicate the signal strength.
Additional messages on the display:
: An horizontal line shifting from bottom to top is displayed when sending an SMS message.
C : The C character is displayed when executing the periodic autotest with SMS sending.
F (flashing) : This character indicates PSTN line fault condition.
8 (blinking) : Indicates an incoming call through the GSM.
Trouble and Fault messages:
0 = VECTOR Plus is not able to turn on the GSM unit.
1 = Wrong or missing serial comunication between VECTOR Plus and GSM unit.
2 = Wrong PIN security code on the SIM card.
3 = No GSM service available
4 = Poor signal level
5 = Battery problem
6 = Unknown general problem

Testing VECTOR Plus

In order to verify the efficiency and the signal quality of the GSM channel, we suggest the
following test: connect a normal telephone set to terminals Ac - Bc of the interface and close to
negative the terminal "GSM". Power up the unit and wait the initialization process is completed
. Execute some telephone calls and evaluate the signal and audio quality of the GSM
(see display)
connection.

Jumpers and trimmers

Jumper S1: closed if using Siemens cell phones - open if using industrial GSM engine
Jumper S2: open if using Siemens cell phones - closed if using industrial GSM engine
Jumper S3:
(OFF - TT)
RV5: serves to adjust the GSM unit voltage - 3,85V for industrial GSM engine - 8,5V for
Siemens cel phones.
Siemens cell phones, because it will cause permanent damage of the GSM module)
RV2: adjusts the audio level of the signal received from the GSM unit.
RV3: adjusts the audio level of the signal applied to the GSM unit for transmission.
(NOTE: RV2 and RV3 are factory adjusted to recommended values. Therefore additional adjustment
normally is not needed)
PB1: Tamper switch connected to the TT terminals.
PB2: Microprocessor reset switch.
(only when using standard cell phone)
closed disables the tamper switch
(WARNING: Avoid mounting the industrial GSM engine if voltage is adjusted for
(correct value 0000)
5