- ページ 9
ストレージ Dell PowerVault MD3000iのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Dell PowerVault MD3000i 46 ページ。 Configuration for vmware esx server software
Dell PowerVault MD3000i にも: チューニング・マニュアル (32 ページ), サポートノート (22 ページ), アップグレードマニュアル (28 ページ), 交換マニュアル (4 ページ), 設定マニュアル (10 ページ)
11 The installation is now complete. Click Done to close the installation
wizard.
NOTE:
To verify successful installation of the application server, run services.msc,
and verify that the cimserver service has been installed and has started along with
the Jetty6-Service service. Also note that after the application server has been
rebooted, the name of the CIMOM service will change to Pegasus CIM Object
Manager.
Application and vCenter Server Configuration
After the application server has been installed, verify the Dell Storage
vCenter Plug-In has been successfully registered with the vCenter server.
Open a vSphere Client to the vCenter Server, and select Plug-insManage
Plug-ins. You should see the Dell Storage vCenter Plug-In listed as enabled. If
it is listed as disabled with an error message stating that it cannot
communicate with the application server, verify that the port number defined
for the Jetty server is enabled to pass through any firewalls that may be in use.
The default Jetty TCP port number is 8084 and 8081.
After the application server and vCenter server have been configured, you
should now see the Dell Storage vCenter Plug-in icon on the home page of
the vSphere Client under the Solution and Application section as shown in
Figure 2.
Dell MD Storage Array vCenter Plug-in
9