SERIAL NUMBER 14-000001 AND UP
Engine Does Not Run
**
M axi Heat 500IQ will not start ( The engine will crank over ,but not run) Isuzu Genset
Note : I f the unit has a shocker valve, check the value and make sure the shocker is open.**
❏ Ensure the unit has enough fuel.
❏ Go through and check all the connections and most importantly check the
emergency shutdown connection to make sure the connection is secure.(Isuzu
Engine Timer Module-921432/ Cat C1.5 T4F- 650302)
❏ If all connections are secure then check to see if the engine is getting fuel.
❏ Pull the return line on the fuel pump and turn the engine over to see if the fuel
pump is working correctly. Loosen the injector line at the injector to see if there is
further fuel flow.
❏ The unit is getting fuel and the Fuel pump is working, find the fuel solenoid on the
engine. Check the fuel shut off solenoid to ensure plunger retracts (example "A",
solenoid plunger retracts from voltage on hold wire)
❏ If the pump works when an auxiliary power source is applied then trace through
wiring for loss of voltage. Power is pulled from the engine starter and goes
through the temp and oil pressure switches. Check schematic for further testing.