- ページ 18
クックトップ Miele KM 360-1 GのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Miele KM 360-1 G 28 ページ。 Gas-hobs
Miele KM 360-1 G にも: 取扱説明書 (28 ページ), 取付説明書 (24 ページ), 取付説明書 (28 ページ)
Gas connection
The gas connection must be in
accordance with national and local
regulations.
The relevant building regulations
must also be observed.
Natural gas / liquid gas
The gas connection must be so sited
that it is not adversely heated when the
appliance is in operation.
Pressure Test Point.This is provided on
the gas regulator (supplied for natural
gas).
^ Loosen the screw in the test point
until it is free in its housing. The
screw is retained in this position.
^ Connect the hose from the pressure
gauge.
^ Reassemble one of the large burners,
turn on the gas and manually light the
burners.
18
Gas pressure must be set by the
approved gas fitter as shown on the
data plate:
Natural gas
ULPG (Propane/Butane)
^ Disconnect gauge and screw in the
test point screw.
When the gas hob has been
installed it is essential to check that
neither the gas pipe nor the
electricity cable is in contact with hot
parts of the appliance or hot gas
exhaust.
If a flexible connection is installed
make sure it does not touch moving
parts of the kitchen furniture, e.g. a
drawer.
A full operational test and a test for
possible leakages must be carried
out by the fitter after installation.
1.0 kPa
2.75 kPa