- ページ 4
産業機器 ABB C1300のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。ABB C1300 16 ページ。 Advanced circular chart recorder
4
C 1 3 0 0/A DVA N C E D C I R C U L A R C H A R T R E C O R D E R | C I/C 1 3 0 0 - E N R E V. C
2
Specification
Mechanical data
• Protection IP66/NEMA4X
Dimensions
• Height: 368.8 mm (15.23 in)
• Width: 382.0 mm (15.04 in)
• Depth behind panel: 141.5 mm (5.57 in)
Materials of construction
Case material:
• Glass fibre- filled reinforced polyester
Window material:
• Polycarbonate
Weight
• 6.6 kg (approx.) (14.55 lb)
Electrical
Power Supply range
• 100 to 240 V AC +/- 10% (90 V min to 264 V max AC)
Power consumption
• <30 VA (typical for full specification unit)
Inputs/Outputs
Universal analog inputs
• Up to 2 standard, (up to 4 optional)
Analog outputs
• Up to 4 standard, range 4 to 20 mA, maximum load 750 Ω
Relay outputs
• Up to 4 standard
• Up to 8 optional ( 2 x 4 relay module)
• Fully programmable. Contacts rated at 5A @ 240 V.
Digital Inputs
Input
2 standard per Input module, 8 per option module. Minimum
pulse duration 250 ms
• Volt Free
• TTL
Output
• 5 V TTL
• 5 mA per output
Environmental data
Ambient Operating Temperature
• 0 to 55 °C (32 to 130 °F)
Ambient operating Humidity
• 5 to 95 % (non-condensing)
• 5 to 80 % (chart only)
Approvals, certification and general safety
• CSA general safety
• UL general safety
Emissions & Immunity
• EN 50081-2, EN 50082-2
• IEC 61326 for an industrial environment
• CE Mark
3
Installation
NOTICE
Locate the recorder in a position where its temperature and
humidity specification will not be exceeded, and ensure that
it is suitably protected from direct sunlight, rain, snow and
hail.
A – Close to sensor
B – At eye-level location
C – Avoid vibration
Figure 1 General requirements
NOTICE
Select a location away from strong electrical and magnetic
fields. If this is not possible, particularly in applications
where mobile communications equipment is expected to be
used, screened cables within flexible, earthed metal conduit
must be used.
0 °C
(32 °F)
min.
A – Within temperature limits
0 to 95% RH
0 to 80% RH
B – Within humidity limits
C – Use screened cables
Figure 2 Environmental requirements
Minimum
Sensor
55 °C
(131 °F)
max.