- ページ 18

溶接システム Miller Axcess 300のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Miller Axcess 300 44 ページ。 Arc welding power source and wire feeder with meters
Miller Axcess 300 にも: オーナーズマニュアル (36 ページ), オーナーズマニュアル (48 ページ)

Miller Axcess 300 オーナーズマニュアル
3-12. Selecting a Location and Connecting Input Power (Linking For 200/230/460 Volts
Model Only)
18 in (457 mm)
for airflow
Have only qualified persons make this installation.
1
Rating Label
Check input voltage available at site.
Remove wrapper.
2
Jumper Link Label
OM-1321 Page 14
Tools Needed:
200 VOLTS
2
3/8 in
3/8 in
GND/PE
Connect First
1
Size and ratings must comply with applicable
codes (see Section 3-11). Install conductors in
conduit or equivalent into a deenergized line
disconnect device.
Do not overtighten
jumper link nuts.
230 VOLTS
3
Jumper Links
Move jumper links to match input voltage.
Reinstall wrapper.
Y Special installation may be required where gasoline or
volatile liquids are present − see NEC Article 511 or
CEC Section 20.
GND/PE
L1
L2
L3
3
460 VOLTS
Ref.
S-072 135-B
Ref. 801 768-C