- ページ 10
産業機器 Burkert 6519のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Burkert 6519 17 ページ。 Solenoid valve
Burkert 6519 にも: マニュアル (4 ページ)
6.2.1 Installation of the pilot valve Type 6106 (for
valve type 6516 / 6517)
0 = rest position
1 = switching
position
10
→
Installation always in the
position shown; if required,
turn coil by 180 °.
→
Screw the housing of the pilot
valve to the housing of the
main valve using 2 screws.
Observe tightening torque of
max. 0.5 Nm.
→
Mount solenoid coil and
screw down using M2 screws.
Observe tightening torque of
max. 0.15 Nm.
english
6.2.2 Installation of the pilot valve Type 6014
(for valve type 6518 / 6519)
Manual control
(can be locked
by pressing and
turning)
→
Screw the housing of the pilot
valve to the main valve.
Observe tightening torque of
max. 1.5 Nm.
→
Connect the coil to the core
guide tube.
The coil can be turned
by 4 x 90° (for block
assembly only 2 x 180°).
→
Screw down the coil with
a nut using an open-end
wrench (the device may be
damaged if other tools are
used, e.g. pliers).
Observe tightening torque of
max. 5 Nm.