Types 6516 – 6519
Degree of
IP65 as per DIN EN 60529 / IEC 60529 with
protection
correctly connected and fitted cable plug,
e.g. Bürkert Type 2506 (Type 6516/6517) or
Type 2508 (Type 6518/6519)
Permitted
Filtered compressed air oiled and unoiled, neutral
media
gases
Operating
Unless otherwise indicated on the type label, the
duration
solenoid system is suitable for continuous operation
The following values must also be observed for valves with
UL/UR approval:
Valve types
Fluid temperature
6518
–10 °C...+55 °C
6519
Observe temperature restrictions on account of approvals.
1)
To prevent the expanded compressed air from freezing, its pressure dew
2)
point must be at least 10 K lower than the medium temperature.
8
Type 6519 for extended
temperature range
Ambient temperature
Fluid
–10 °C...+55 °C
Air
english
Important information for functional reliability during continuous
operation!
If the equipment is switched off for a long period, it is recom-
mended to activate the valves at least 1-2 per day.
Service life:
High switching frequency and high pressures reduce the service life.
The valves operate maintenance-free.
5.5 Materials
The seal materials depend on the housing materials:
Housing
PA
material
Seal
NBR, PUR
material
5.6 External control pressure
If valves are designed for auxiliary control air, the compressed air
supply must be connected to port 12 or 14 (control pressure port).
Control pressure: at least 70 % of the operating pressure to
port 1 (minimum control pressure 2.5 bar)
AL
AL
anodized
ematalized
NBR
FKM, NBR
PU, NBR,
VA
FKM