The installation of junction point* (fig. 4)
• Turn the water off at the mainline on the highway of cold
water-supply.
• Open the kitchen mixer tap in order to depressurize water
pipe.
• Unscrew cap nut of flexible connection at the mainline on the
highway of cold water-supply, stand for mixer tap.
ATTENTION! In the flexible tube, after a pressure
release, a small amount of water may remain. When
disconnecting the flexible connector, use a capacity
of about 200 ml to drain the remaining water in the
tube.
• Screw the cap nut of the junction point to the threads of
mainline on the highway of cold water-supply.
ATTENTION! Ensure that the seal pad is in place and
is not damaged when mounting the product.
• Screw the cap nut of flexible connection on the threads of
junction point.
• Close the inlet tap of the connection unit and, having supplied
water from the cold water supply line, make sure that the
connection is hermetically sealed.
• Joint the tube JG.
* * The manufacturer reserves the right to use the connection points and cranes of a similar design. If you have any questions, please contact the service provider.
6
Fig. 5а
Fig. 5b
Inlet tap set to position
«Closed»
Key lock clip
Junct
ion point
Seal pad
Cold water-
supply
Fig. 4
How to connect the pipes JG (fig. 5a) Pull
out the key lock clip from under the plastic
sleeve, insert the pre-tipped end of the tube into
the choke bean to the depth of about 15 mm to
the stop and emplace the clip.
How to disconnect the pipes JG (fig. 5b)
Pull the locking clip out from under the plastic
sleeve and, pressing the end of the plastic
sleeve, pull out the tube.
Check the strength of the tube. At
an effort of 8-10 kgf the tube
should not be pulled out.