4. The device and the principle of operation
Main parts:
1-Body
2-Preliminary treatment unit
3-Final treatment unit
1) The body of the water purifier (1) consists of an upper plate in which two collectors
are fixed to connect the exchangeable filter modules. The top plate is covered with a
decorative cover, fixed with three plastic clips. The main part of the body is a replaceable tank
with replaceable backfill.
2) The pre-filtration unit (2) includes a plug-in filter cartridge K5.
3) The post-filtration module K7 is included in the final water treatment unit.
How does the water purifier work?
From the cold water supply network water enters the inlet of the water purifier and passes
through the preliminary water treatment unit. Further, through a non-return valve, water enters
the tank with a replaceable backfill. Softened water passes through the final water treatment
unit and further to the consumer.
5.
Installation
ATTENTION! Installation of the
water purifier must be carried
out only by persons,
authorized to carry out this
type of work.
Determine the convenient location
of the water purifier. In this case,
pay attention to the fact that the
supply tubes pass freely, without
kinks and folds.
The water purifier should be
installed on a flat, hard surface; be
distanced or isolated from sources
of heat (cookers, boilers, hot
water pipes, dishwashers or
washing machines, etc.).
6. Starting
Before using the water purifier, it is necessary to wash it. Connect the supply pipes and perform the washing procedure of the
modules.
Step 1
Connect the supply pipes following the diagrams below.
Connecting the JG pipes
Pull the locking clip (2) out of the plastic bushing (1) and
insert the pre-moistened end of the tube (3) into the sleeve
bushing to the stop at approximately 15 mm depth and set
the clip (2) in place. Check the strength of the tube fixation
(3): at an effort of 8-10 kg the tube should not be pulled
out.
4
К5
К7
How to disconnect the JG tubes
Pull the locking clip (2) out from under the plastic sleeve
(1) and pull the tube (3) by pressing the end of the plastic
sleeve. For pressing, use the wrench (4) to disconnect the
pipes included in the water purifier kit.
K5
K7
Fig. 1
inlet
outlet
Fig. 2