13. Warranty
Installation, operational, storage and transportation rules described in this manual should be maintained. The
manufacturer is not responsible for operation of the DWM and possible consequences, in case if:
- DWM or components have visible mechanical, thermal or chemical damages;
- requirements for installation and operation of the DWM described in present manual were not carried out.
The lifetime of the parts of the DWM is:
DWM case – 5 years* starting from the manufacturing date;
Connecting pipes – 3 years* starting from the manufacturing date;
Purified water faucet – 3 years* starting from the manufacturing date;
The lifetime (capacity) of the replacement filter cartridges is:
Name of the replacement filter cartridge
K5
K2
Membrane cartridge Aquaphor RO-50S
K7M
Data listed above based on the average consumption of the purified water 10–12 liters per day.
Attention!
* Regardless of the operation starting date.
** Lifetime (capacity) of the replacement filter cartridges may depend on incoming water quality. If in the source water
contains large amounts of insoluble impurities then cartridges K5 and K2 should be replaced after 1–2 month of operation.
*** Lifetime of the membrane cartridge is depended upon the efficiency of the prefiltration and water conditioning units
Please replace cartridges in a proper time.
Warranty period of the DWM operation (except for replacement filter cartridges and membrane cartridge) is 2 year starting from
the purchase date.
The storage period of the DWM before operation is maximum 3 years 1.5 year in the temperature range from +5 to +38 °C
(40 to 100 °F) with intact packing.
If you have any claims regarding the operation of your DWM, please contact the seller or manufacturer.
Manufacturer is not responsible for operational faults occurred due to inappropriate installation or maintenance.
Manufacturer is not responsible for the operational faults occurred due to inappropriate replacement cartridges.
18
Lifetime (capacity) of the replacement filter
cartridge
3–4 months *
3–4 months *
1,5–2 years **
1 year