HOUSIng InStaLLatIOn
1. Using the filter housing assembly to mark the position of the 2 mounting screws, making sure
there is room for maintenance, drill 2 x 3mm holes for the mounting screws. Insert the wall
plugs; screw the screws in the gap for the Mounting Bracket.
2. Apply 2 turns of Teflon/Thread tape to the nipple side of the quick adapter fittings (items 4).
Screw the nipples into the inlet and outlet of the filter housing assembly. Connect the tubing
to the outlet and the inlet sides. Screw the nipple on the other end of the outlet tube into the
3/4" X 1/4" BSP brass reducing coupling.
PLUMbIng tHe SySteM
1. Locate the water shut-off valve for the cold water feed line you choose to use for the supply. To
assure you are using the cold water line, turn on both the hot and cold faucet. After the water
is warm to touch, feel the pipes under the sink. It will be easy to identify the hot and cold pipes.
2. Close the cold water valve. Turn on the cold water faucet to assure that the line is completely
shut off and the line is drained. If no shut off valve is located underneath the sink, turn off the
main supply at the entry to the house.
3. The Aquaport water purifier is supplied with an installation kit that allows connection to
a dishwasher type cold tap with a 1/2" BSP male thread. If a convenient tap is not available,
you may either have one installed or purchase the suitable inlet fittings from your supplier.
Connecting to the cold water main will require a qualified plumber. There must be a tap to turn
off the water for maintenance. Use cold water only.
WarnIng !
Excessive pressure or water hammer can damage plumb-in systems. Do not, under any
circumstances, connect to a pressurised water supply without testing pressure with an accurate
gauge. If pressure is above 125 psi (875 kPa) day or night, or if any water hammer problems exist, a
high quality pressure limiting / anti-hammer valve must be installed.
A non-return valve must be installed in the water supply line or between the supply line and the
first filter housing. This will ensure no water returns to the supply.
The responsibility must always lie with the installer to check the water-tightness of all fittings and
connections after the product is subjected to full line pressure. The installation must be checked
last thing at night and again early the next morning after the day of installation, to make sure there
are no drips from inadequately sealed connections.