P*CAR10 / P*CAR20 / P*CDR20 / TC10 / TC20
The refrigerated unit for chocolate always works with ventilated refrigeration and the controller does not have the keys
are not needed.
The inside humidity is always less than 45% thanks to the conformation of the aluminum panels covering the serpentine.
The moisture level cannot be set and is only viewable with a special controller OPT-TVU (optional).
PM-VBR10 / PC-VBR10 / PM-VBR13 / PC-VBR13
The unit P * -VBR10 can be used for storing wine or for keeping at serving temperature only red wines. You can not set temperatures lower than
the indicated one.
INSIDE VENTILATION
The internal fans of P * -VBR10 units are connected directly to the general switch, they do not need to be operated by the user and during their
operation no warning light is shown on the display.
TURNING THE LIGHTS ON
The lights of the upper unit "B" light up together with the lower unit "A" by pressing the Key on controller of the "A" unit. If you want to keep off
the top unit "B" while the "A" unit is on you must act manually on the switch (I-O) of the upper unit "B", placed next to the controller.
The temperature controllers of all the showcases are blocked so that the user cannot set lower temperatures than those planned PARETE VINO
+3 ° C (excluding P * VBR10 and CAR10-20 +12 ° C) TECA +4 °C (excluding TC10-20 +12 °C). It is not allowed to enter the hidden parameters
and modify these values. The showcases are not designed and built to operate at low temperatures. Failure to comply with this provision will
invalidate the warranty.
If the display shows the warning light
ed the safety limits set by the manufacturer. The reasons may be as follows:
• The space at the bottom of the unit (8 cm) was blocked, preventing the air exchange.
• The ambient temperature and humidity are too high.
• The condenser is completely blocked with dust, compromising the ventilation. Clean it as indicated in section 4.1.
5.2 HEATED FRAME AND RAIL
An heating element is installed on all the showcases (Parete -> Frame ) (Teca -> Rail) which can be activated with the AUX key on the
thermo-regulator (excluding models with
This technical device solves the problem of condensation on the metal parts due to the difference of temperature between the
inside of the showcase and the ambient temperature, especially in places with very high temperature and humidity.
It is very important to use this feature in tropical countries and marine locations because even a small presence of condense for long
periods may damage the external decorative coating of the showcase.
In locations with continental climate with normal temperature and humidity conditions it is not necessary to use this device. The
same goes for the showcase set at the storage temperature (+14 +16 °C).
KEYS FUNCTION ON THE CONTROL PANEL
To view / edit the setpoint
To decrease temperature
To increase temperature
MINIMUM ADJUSTABLE TEMPERATURE

CONDENSER TEMPERATURE ALARM

it shows that the temperature detected by the second probe placed on the condenser has exceed-
)
MEANING OF THE WARNING LIGHTS
Compressor on
Defrosting on
(ON) Actual unit temperature
(FLASHING) Set point in progress
ENGLISH
+14 / +16 °C
SET
14 °C
TA 30°C
and
which
SETTINGS
+14 / +16 °C
SET
14 °C
TA 25°C