05 Main Menu (Page 4)
Switch Off Device
In addition to the Auto-Power-Off function, the user can turn off the device manually.
It's recommended that the user turn off the device (or to wait for auto-power-off)
before replacing the battery in order to save statistic counters. Otherwise the changes
since the last power up will be lost.
To turn off the device go to this menu item, wait until the display shows "0" then
press the button.
Extended Functions Menu
The Extended Functions Menu has three sub-menus:
Heater Menu
Mod Menu
Value Menu
The Extended Functions Menu offers many options to accommodate even the most
discerning user. Once the user preferences are set, they rarely need to be changed.
The more advanced settings were placed in the extended functions menu.
The many options may frighten some of the users initially. But without the extended
functions menu the mod would not be able to address all different customer
requirements. Please take a bit of time to get familiar with the menu. We are sure, as
soon as you have gained an overview, setting your preferences will be relatively
easy.
Error Messages
If an error occurs, the mod directly jumps to the error menu and displays the error
number and a mnemonic (short-term) description.
The possible error messages are:
0 OvrVolt:
The input voltage is too high. The dicodes 2380 designed for the use of one or two batteries.
If one battery is selected in the Extended Functions Stack Mode menu (Value=1) and the input
voltage exceeds 4.5V "OvrVolt" will be displayed. With two batteries selected (value=2), the error
occurs for an input voltage >8.6V. Reduce the input voltage to the specified range. With stack
mode set to "0" (automatic detection) the error is displayed for voltages >8.6V.
1 ChkAtom: No atomizer detected or open coil.
2 TempRef: A problem during the temperature reference measurement occurred
3 HighR:
The resistance of the coil is too high for the selected output power. The maximum output voltage
is 12V and current is 15A. This specification together with a maximum output power of 80W
leads to a resistance range of 0.4-1.7 Ohms. Also see "8 LowR". Higher and lower resistances
are possible, but the power has to be reduced accordingly.
Example 1: With a 4Ohm coil the maximum power is (12V)²/4 Ohm=36W.
Example 2: With a 0.12Ohm coil the maximum power is (15A)²*0.12 Ohm= 27W.
NOTE: The 12V and 15A maximums will limit the usable resistance range.
4 OverCur: Short on coil or coil breakdown (open)
5 LowBat:
The battery voltage under load (with current drained from it) has reached the minimum discharge
level defined in UbatMin (in the Extended Function menu). The Ubatmin range depends on the
number of batteries used.
6 EleHot:
The electronics have overheated and need to cool down. This error will not occur with normal
usage of the mod.
7 TimeOut: The maximum puff-time is limited depending on power. For a power <20W it is 20 seconds. Above
20W it decreases by 0.5 seconds per Watt, down to 10 seconds. Above 40W it stays at 10
seconds.
8 LowR:
The coil resistance is too low for the selected power, please see "3 HighR".
Settings related to the heater or coil