05 Main Menu (Page 6)
Main Menu
Extended Functions
Heater Menu
The Power Boost Mode enables an initial short term high power pulse applied to the coil (boost). The
boost power is the value of the parameter "Power Limit". Beside 3 selectable initial boost lengths, further
options generate a periodic boost pulse with different length and repetition rate. An initial boost is for quick
coil heat-up. The periodic boost lets the coil temperature pass a certain range all the time. In this case
different flavours within the liquid, which all develop their taste at different temperatures, are all addressed
by the varying temperature.
Main Menu
Extended Functions
Heater Menu
2. Heater Protection Mode (only when Expert Mode=1)
The heater protection mode is a periodic interruption of the power applied to the coil.
The duration and the repetition rate of the interrupts is selected by means of the para-
meter "Heater Prot" in the extended functions mod-menu. The repeated power
interrupt helps to avoid a break in liquid flow and thus an increase in temperature.
The table below shows the relation between power interrupt and appliance time
in dependence of the parameter "Heater Prot":
Value Heater Prot
1
2
3
4
5
6
7
8
9
10
3. Power Boost Mode
We recommend to set the normal power (not the boost) to much lower values, when
using the periodic boost, because the average power is increased by the boosts and
temperature gets higher therefore.
Wert Boost Time
1
2
3
4
5
6
7
8
9
10
On-Time [ms]
Off-Time [ms]
400
600
800
1000
1350
2000
2000
2000
2000
2000
(only when Expert Mode =1)
Boostzeit [ms]
Zeit auf Nennleistung
300
450
600
800
1000
100
150
200
250
300
Powerfactor
0.80
100
0.86
100
0.88
110
0.89
120
0.90
150
0.91
200
0.92
180
0.93
150
0.95
100
0.96
80
Effektive Leistung
[ms]
(bei 5W Nennleistung)
Start-Boost
-
Start-Boost
-
Start-Boost
-
Start-Boost
-
Start-Boost
-
6.9
700
7.17
800
7.36
900
7.6
1000
8.0
1000