05 Main Menu (Page 1)
Power Up
Power Up increases the power to the Power-Limit value and then rolls over to 5W.
Power Down decreases the power down to 5W and then rolls over to the Power-Lim
value. The Power-Limit value is adjusted in the Extended Functions Sub-Menu "Heater"
and provides a protection feature for atomizers which are not prepared for high
wattage or to reduce the power range intentionally. The wattage step size is 1 Watt
below 20W and 2W above, but can be set to 0.5W and 1W respectively in the mod-
menu with "Half Watt=1".
With temperature controlled vaping activated, the power setting is the power limit
for the temperature regulator. If the power level is smaller than the value needed to
achieve the selected temperature, the operation changes from a temperature regulator
to a temperature limiter. If the power level is sufficiently high, it sets the heating up
speed of the coil until the set-point temperature is reached.
In the operation mode "Bypass" (mechanical mod), the power setting is not available,
because the power is defined by the battery voltage and coil resistance. The menu
items "Power Up/Down" are not displayed in this case.
Temperature Up and Temperature Down
This Menu items are
selected
selected operation mode. The Temperature Up/Down menu sets the setpoint for the coil
temperature during vaping. The temperature setpoint can be selected from 120°C to
280°C (250°F- 540°F) in steps of 5°C (10°F). To achieve a high precision temperature control,
a correctly performed reference measurement (TempCal Init) is mandatory, see next item.
Manual Coil Temperature Calibration
This Menu item is
Heater Control menu item below). For the use of temperature controlled vaping, the
calibration measurement is a very important part of it. The Temperature calibration
measures the coil resistance at room temperature (20°C) as the reference for
temperature controlled vaping. This together with the wire's temperature coefficient
enables the mod to calculate the coil's temperature.
The calibration must be confirmed in a second step to avoid accidential activation.
After confirmation the display shows "process" until the calibration completed.
It is extremely important to understand, that, if the calibration is performed at a
temperature other than 20°C, the control will regulate a constant temperature, but
with an offset deviation. So take the ambient temperature durcing the temperature
adjustment in to account. Similiar, if a wrong temperatuer coefficient was adjusted, the
actual temperature might deviate dramatically from the set-point (here it is a factor
and not an offset).
Always perofm a caibration, when a new atomizer is attached, even if it is made from
the same coil material
Coil Resistance and Coil Temperature
This is a display only menu item. The coil resistance is displayed in a range from
0.00 to 9.90 Ohms. If temperature controlled vaping is selected, the current measured
coil temperature is also displayed, if not, the display shows T ---.
If the display does not show 20°C even with colled down atomizer, it is recommeded
to perform a manual calibration.
and
Power Down
only available and displayed if temperature controlled vaping is
(see Heater-Control menu item below). So the menu structure adapts to the
only displayed if temperature controlled vaping is selected
(see