FIG 2
Installation & Assembly
Remove the table insert .
Block the spindle with current sawing tool; remove the flange (FIG 3)(FIG 4) (thoroughly clean when
reassembling)
Note the direction of the teeth when replacing the saw blade. Replace the various connection elements
(FIG 5)
Mounting and Adjusting the Splitting Wedge
Loosen the flange base with a 13 mm wrench and insert the splitting wedge. Adjust the splitting wedge and
be sure to maintain a distance of approx. 3mm to the saw blade (FIG 6). Securely fasten the splitting wedge
with screw. Check that the splitting wedge is parallel to the saw blade by means of the table insert (FIG 7).
Adjusting the Longitudinal Limit Stop
The longitudinal limit stop must be adjusted so that it is exactly parallel to the saw blade. First set the
FIG 4
FIG 6
FIG 3
FIG 7
7