Lubrication

Prior to delivery the actuator is filled with 2.5 l oil in factory.
Fig. 1:
Min. oil quantity;
approx. [l]
Min. oil level [mm]
under inspection
screw
Table 3: The arrow indicates the position of the inspection screw
actuator, replace the highest inspection screw with the separately delivered vent screw.
6.1

Lubricants

PME 120AI
(with integrated electronic unit)
Table 4:
7

Mounting

7.1

Actuator check

- Is the actuator filled with the appropriate oil type?
- Is enough oil in the actuator?
- Did you fasten the separately delivered vent screw in the highest bore (depending on the mounting
orientation)?
- Has the actuator integrated or separate electronic unit?
7.2

Mounting orientation

All mounting orientations seen in Figure 2 are permissible. To facilitate mounting and maintenance,
however, it is recommended to use orientation IMB 3.
7.3

Mounting instructions

- Make sure that the actuator is accessible from all sides to ensure convenient handwheel operation,
electrical connection, and replacement of assemblies.
- Avoid direct exposure to rain, snow and other environmental influences. Select the mounting site
accordingly.
- Exclusively mount the actuator on a rigid, non-vibrating support to avoid relative motion between
the actuator and the valve.
- When mounting the actuator close to heat sources use an insulating layer or shielding.
8
Electrical Part Turn Actuators for Continuous Modulating Control PME120AI (Contrac)
1)
1)
2)
IMB 3
IMB 6
2.2
45
Actuator type
1)
2)
2)
IMB 8
IMB 7
2.5
2.2
2
42
1)
and the vent screw
Ambient temperature
1)
(-25)
- 10°C ... + 55°C Mobil SHC 629
Lubrication
1)
2)
1)
2)
IMV 5
2.2
2.5
20
23
2)
. After having mounted the
Motorbearing
Oil type
(grease)
ESSO Beacon 325
A68-2005-003 EN
1)
2)
IMV 6
2.5
17