- ページ 12
リモコン digico A-CONTROL8のPDF スタートマニュアルをオンラインで閲覧またはダウンロードできます。digico A-CONTROL8 15 ページ。 For 4rea4
5.2 4REA4 connection
Connect the A-CONTROL8 to a 4REA4 Network port using a CAT5 cable up to 100m
long.
Power up the A-CONTROL8 by plugging the external PSU into the DC In socket or
connecting using a CAT5 cable to a PoE+ switch. The port Lnk/Err indicator flashes at
a steady rate when the link is established. The unit Name and IP address are displayed
on the LCD Displays for easy identification of the unit. After a few seconds the A-
CONTROL8 will display the assignments and functions if any have been set for the
unit.
is not the same version as that in the 4REA4, then the 4REA4
will automatically update the A-Control firmware at power up.
5.3 Ethernet Switch
For parallel connection of multiple A-Control Remote Controllers you can use a standard
Ethernet switch.
standard (25.5W at source) is required. Check that the overall
power rating is enough to provide for all IP Remote
Controllers you wish to connect (allow 25W per A-CONTROL8
unit).
A-Control8 Getting Started Guide
If the firmware in a connected A-Control Remote Controller
For PoE (Power over Ethernet), the PoE+ 802.3at
12
AP11452 Issue 1