- ページ 7

配管製品 Creda 570のPDF インストールとユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Creda 570 12 ページ。 Pumped electric shower

1. Ensure the electricity and water are turned on to the unit.
2. Your shower has 2 control knobs (see Diagram 5).
Knob "A" controls the 2 power settings.
The most popular is "high" indicated by "
There is also a "low" power option "
Knob "B" starts and stops the unit and controls
the temperature of the water.
3. To start the shower turn knob "B" anti-clockwise.
The water will start flowing at around 15° knob rotation
(1 o'clock) and the motor will switch on at around 30°
(12 o'clock). The "power" light will illuminate at this stage.
4. Allow about 20 seconds for the temperature of the water to stabilise.
It is recommended that you test the water temperature with your hand before stepping under
the water spray during this period, even if the shower has just been used.
IF WATER IS TOO COLD
Turn knob "B" clockwise in the direction
of the "red dots" a small amount and
continue turning clockwise until you get the
water temperature of your liking.
Wait 20 seconds after each adjustment
for the water temperature to stabilise.
The final adjustment may be anywhere on
the scale.
If after turning fully clockwise water is still
too cold, set shower pattern on shower
handset to outer or inner pattern only.
5. When you have finished showering, turn knob "B" fully clockwise to the "Stop" position.
The motor will switch off and water will stop flowing.
The "POWER" light will go out.
6. Switch off the electricity at the ceiling switch or local isolator.
7. The "
" low power setting of knob "A" reduces the power used by the shower giving a
cooler shower or the option of reduced water flow.
This option is mainly for summer usage, and if this is used then knob "B" must be
re-adjusted.
WARNING: DO NOT SWITCH THE SHOWER ON IF YOU SUSPECT IT OF BEING FROZEN.
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.
WARNING: DO NOT OPERATE THE SHOWER IF WATER IS DISCHARGED FROM THE
PRESSURE RELIEF VALVE.
MAINTENANCE IS REQUIRED BEFORE THE SHOWER CAN BE USED.
WARNING: CONSIDERATION SHOULD BE GIVEN TO SUPERVISING THE YOUNG,
ELDERLY AND THE INFIRM WHILST THEY USE THIS SHOWER.
HOW TO USE YOUR CREDA SHOWER
".
" (see note 7).
IF WATER IS TOO HOT
Turn knob "B" anti-clockwise in the
direction of the "blue dots" a small amount
and continue turning anti-clockwise until you
get the water temperature of your liking.
The final adjustment may be anywhere on the
scale.
If after turning fully anti-clockwise, water is
still too hot, adjust knob "A" to "
power setting and re-adjust as above.
Water flow will be reduced on this setting.
7
" low