- ページ 8

配管製品 Creda 570のPDF インストールとユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Creda 570 12 ページ。 Pumped electric shower

SELF HELP
If the shower is not working satisfactorily, make the following checks before calling out the installer.
Any one of these adjustments could restore the performance.
The shower cycles
from HOT to COLD
Water too HOT
Water too COLD
Pump operates
but no water is
delivered
Pump fails during
shower
Spray pattern poor
Water takes longer
to heat up
Water goes cold
while using
shower
Broken parts
Please Note:- The fitting of Spare Parts must be supervised by a suitably qualified person.
Front Cover
Tank-Base Assy
Pump Assy
Camshaft Assy
Tank Clip
RING: 0870 9000 420 (UK Only) / RING: +353 1 842 4833 (ROI Only)
WHAT TO DO IF THINGS GO WRONG (1)
The shower temperature is set too hot causing the thermal cut-out (safety
device) to operate.
Turn knob "B" anti-clockwise (direction of the "blue dots") to increase water
flow.
Slowly increase the water temperature by turning knob "B" clockwise in the
direction of the "red dots" until a comfortable showering temperature has been
reached.
You MUST WAIT approximately 20 seconds for each adjustment to affect the
water temperature.
"
" low power setting may need to be selected.
Increase water flow by adjusting knob "B" anti-clockwise (direction of the "blue
dots").
"
" low power setting may need to be selected.
Increase pressure to water supply e.g. fully open service valve or stop cock.
Check hose is not kinked restricting the water flow.
Clean shower handset.
Check power is on (indicated by "power" light).
Decrease water flow by adjusting Knob "B" clockwise (direction of the "red
dots").
"
" high power setting may need to be selected.
Select inner or outer only handset spray pattern.
Water starvation. Stop pump immediately by turning knob "B" fully clockwise to
the "Stop position".
Check the cold water cistern is full. Ensure water supply pipe is not blocked or
air-locked (see commissioning) with power to shower switched off.
Thermal trip inside motor has operated.
Wait for motor to cool down (approximately 30 minutes)
Clean the shower handset. Select an outer/inner spray pattern.
Thermal cut-out has operated after previous use ("overheat" light is on)
(automatically resets when unit cools down)
"
" high power setting may need to be selected.
Thermal cut-out has operated ("overheat" light is on).
Wait for cut-out to reset.
Check power is on (indicated by "power" light).
Please contact our spares department on 0870 9000 430 (UK Only) or
+385 1 842 8222 (ROI Only) or contact your local distributor

COMMON SPARE PARTS

Cat No. 93590382
Cat No. 93590307
Cat No. 93590313
Cat No. 93590312
Cat No. 93590715
Spare parts can be supplied against any Credit or Debit cards
Or contact your local distributor
PRV Washer
Thermal Cut-Out 50/88°C Cat No. 93597836
Handset
Height Adjuster
8
Cat No. 93795817
Cat.No. 93590736
Cat No. 93593523