- ページ 23

スイッチ Cisco 2948G - Catalyst SwitchのPDF ハードウェアのトラブルシューティングをオンラインで閲覧またはダウンロードできます。Cisco 2948G - Catalyst Switch 30 ページ。 End-of-sale and end-of-life announcement
Cisco 2948G - Catalyst Switch にも: よくある質問マニュアル (7 ページ), 製品サポート速報 (3 ページ)

Cisco 2948G - Catalyst Switch ハードウェアのトラブルシューティング
PS1−Type
−−−−−−−−−−−− −−−−−−−−−−−− −−−−−−−−−−−−
WS−C4008
Modem
Baud
−−−−−−− −−−−− −−−−−−− −−−− −−−−−−−−−−−−−−−−−−−−−−−−−
disable
9600
Power Capacity of the Chassis: 2 supplies
System Name
−−−−−−−−−−−−−−−−−−−−−−−− −−−−−−−−−−−−−−−−−−−−−−−− −−−−−−−−−−−−−−−−−−−−−−−− −−−
Cat4000−c

show time

This command displays the day of the week/month/year and the time in a 24−hour format. This verifies the
operation of the system clock, but also is a reminder that system log messages carry a timestamp. Make sure
to set the time accurately or sync the switch to Network Time Protocol (NTP).
Cat4000−c> (enable) show time
Wed Jan 23 2002, 10:41:22
Cat4000−c> (enable)
Refer to the show time command for more information.

show logging buffer 1023

This command displays system messages from the internal buffer. The show logging buffer command only
gives you the last 20 system messages, while if you add the 1023 keyword, this gives you the last 1023
messages. Many of these messages are strictly informational. Others can contain clues as to the nature of the
problem, whether it is a hardware problem, switch crash, or software problem. When you compare the logs on
several pieces of equipment, verify that the time stamps are correct and issue the show time command.
For example, these types of messages are informational:
2002 Jan 06 16:07:04 %DTP−5−TRUNKPORTON:Port 2/23 has become dot1q trunk
2002 Jan 06 16:07:08 %PAGP−5−PORTTOSTP:Port 2/21 joined bridge port 2/21−24
A message like this one indicates a hw/sw incompatibility:
Module 6 is not supported (46)
A message like this one can indicate a hardware failure:
EARL−3−LTL: Failure to set LTL for module [DEC]
Refer to Messages and Recovery Procedures for a listing of system messages. Use the Error Message
Decoder, Bug Toolkit, and other resources described under the Prerequisites section in this document. Also,
refer to Common CatOS Error Messages on Catalyst 4000 Series Switches for more information.
Refer to the show logging buffer 1023 command for more information:
Cat4000−c> sh logging buffer 1023
2002 Jan 23 11:14:23 %SYS−5−MOD_OK:Module 1 is online
2002 Jan 23 11:14:32 %SYS−5−MOD_OK:Module 5 is online
2002 Jan 23 11:14:35 %SYS−5−MOD_OK:Module 3 is online
PS2−Type
PS3−Type
WS−C4008
none
Traffic Peak Peak−Time
0%
0% Fri Jan 11 2002, 13:37:07
System Location
System Contact
CC