- ページ 5

産業機器 Siemens SINUMERIK 840D slのPDF コミッショニング・マニュアルをオンラインで閲覧またはダウンロードできます。Siemens SINUMERIK 840D sl 36 ページ。 Operator panel front: op 010s
Siemens SINUMERIK 840D sl にも: アップグレード手順 (4 ページ), アップグレード手順 (5 ページ), 取扱説明書 (33 ページ), アップグレード手順 (3 ページ), アップグレード手順 (3 ページ), システムマニュアル (44 ページ), 設備マニュアル (28 ページ), 設備マニュアル (48 ページ), 設備マニュアル (26 ページ), 設備マニュアル (28 ページ)

Siemens SINUMERIK 840D sl コミッショニング・マニュアル

Fundamental safety instructions

1.1

General safety instructions

Electric shock and danger to life due to other energy sources
Touching live components can result in death or severe injury.
● Only work on electrical devices when you are qualified for this job.
● Always observe the country-specific safety rules.
Generally, the following six steps apply when establishing safety:
1. Prepare for disconnection. Notify all those who will be affected by the procedure.
2. Isolate the drive system from the power supply and take measures to prevent it being
3. Wait until the discharge time specified on the warning labels has elapsed.
4. Check that there is no voltage between any of the power connections, and between any
5. Check whether the existing auxiliary supply circuits are de-energized.
6. Ensure that the motors cannot move.
7. Identify all other dangerous energy sources, e.g. compressed air, hydraulic systems, or
8. Check that the correct drive system is completely locked.
After you have completed the work, restore the operational readiness in the inverse sequence.
Electric shock due to connection to an unsuitable power supply
When equipment is connected to an unsuitable power supply, exposed components may
carry a hazardous voltage that might result in serious injury or death.
● Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV-
SINUMERIK Software Update Tool
Commissioning Manual, 03/2018, A5E42187770B AA
WARNING
switched back on again.
of the power connections and the protective conductor connection.
water. Switch the energy sources to a safe state.
WARNING
(Protective Extra Low Voltage) output voltages for all connections and terminals of the
electronics modules.
1