Procedure
Figure 5-4
1. Grease the bearing surfaces ① of the load cell with a bearing lubricant.
2. Insert the load cell into the mounting plates together with the pressure pieces.
3. Lower the load bearing implement onto the load cells.
5.2.6
Checking the installation
CAUTION
Destruction of the load cell, pressure piece set and mounting plates
Check that the load cell, pressure piece set and mounting plates are installed correctly, e.g.
by checking the mounting dimensions and oscillation distances. Incorrect assembly can
lead to the destruction of the load cell and the pressure piece set.
1. Check the installation of the load cell:
CP-S SA
Operating Instructions, 04/2009, A5E02522341B
Installing the load cell and pressure pieces
– The load bearing implement must be able to oscillate freely.
– The load cell should be aligned as vertically as possible.
Installation
5.2 Installing mounting plates
25