- ページ 10
コントロールパネル Actulux SVM 24V-8AのPDF ユーザーマニュアルと設置手順をオンラインで閲覧またはダウンロードできます。Actulux SVM 24V-8A 11 ページ。 For fire ventilation
- 1. Table of Contents
- 2. General Description
- 3. Safety Rules During Installation and Operation
- 4. Explosion Danger
- 5. Installation
- 6. Yearly Legal Requirement of Maintenance and Control
- 7. Connection to Motor- (Actuator) Outputs and Line Monitoring
- 8. Current Limiter Type LIP
- 9. Connection of Smoke-/Heat Detectors
- 10. Comfort Ventilation - Connection and Settings
- 11. Fuse Specifications
- 12. Connection of Weather Sensor / Close All Function
- 13. Special Functions
- 14. Cable Sizes
- 15. Part Nos. and Accessories
- 16. Technical Specifications
Control for Fire and Comfort Ventilation Type SVM 24V-5A / SVM 24V-8A
Part nos. and accessories
Spare parts
Name of part
no.
121620
Control PCB
211061
Power supply 150W 27VDC MW
211071
Power supply 200W 27VDC MW
211210
Circuit breaker 10A
800248
Batteri 12V/7,2AH 151x65x98mm
111789
Fire switch/reset IP40 Actulux
111701
Replacement glass for BVT
111725
Fireswitch WSK/BVT in IP65 Box
111960
Rain sensor 250VAC / 24VDC
111961
Wind and rain sensor 250VAC /24VDC
111735
Heat detector+base 75 degree
111741
Heat detector+base 90 degree
111740
Smoke detector, optical
111742
Smoke detector, Ion detector
111753
Comfort switch OPUS w housing
111758
Comfort switch FUGA w housing
111760
Weekly timer 1 channel
111761
Comfort sw.up/down OPUS IP44
111767
AUTO MAN switch OPUS w housin
111770
Room thermostat RTR w.resis.
111655
Relay PCB extra 2Xoutp.in box
111892
Transmitter for Wind and Rain
111894
Remote control w/receiver SVM
121615
Priority switch + Add-on SVM
Description
Main board
Power supply 230VAC/27VDC for 5A control
Power supply 230VAC/27VDC for 8A control
Automatic fuse 10A / input terminal
Battery for 24V / 5A controls / 8A controls
Fire switch IP 40
Replacement glass for fire switch
Fire switch built in IP65 box
Rain sensor closes everything when raining
Wind- and rain sensor closes everything when raining or
strong wind
Heat detector 75 degrees temperature activation
Heat detector 90 degrees temperature activation
Optical smoke detector
Ion smoke detector for invisible smoke
Comfort switch Opus complete with housing
Comfort switch Fuga complete with housing
Weekly timer, can e.g. close everything in the evening
Comfort switch Opus 44 white
Switch Auto. man. OPUS white, activates room
thermostat or weekly timer
Room thermostat for control of comfort ventilation
Board with 2x2 extra relay outputs 30V 0,5A
Wireless weather signal together with #111894
Remote control for comfort
Firemans button, override the alarm and closes
18
Control for Fire and Comfort Ventilation Type SVM 24V-5A / SVM 24V-8A
19