Attaching Module Interface Cables
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
Warning
beams or view directly with optical instruments. Statement 1051
Figure 5
Light out
of fiber
SC Connector
The SC connector, shown in
the external SMF or MMF network.
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
Warning
beams or view directly with optical instruments. Statement 1051
Make sure that the optical connectors are clean before making the connections. Contaminated connectors
Note
can damage the fiber and cause data errors.
Always insert the network connector completely into the socket. A secure connection is especially
important when you are establishing a connection between a module and a long distance (1.24 miles)
(2 km) network or a module and a suspected highly attenuated network. If the link LED does not light,
try removing the network cable plug and reinserting it firmly into the module socket. It is possible that
dirt or skin oils have accumulated on the plug faceplate (around the optical-fiber openings), generating
significant attenuation and reducing the optical power levels below threshold levels so that a link cannot
be made.
Use extreme care when removing or installing connectors so that you do not damage the connector
Caution
housing or scratch the end-face surface of the fiber. Always install protective covers on unused or
disconnected components to prevent contamination. Always clean fiber connectors before installing
them.
Installation and Configuration Note for the Catalyst 4500 E-Series Supervisor Engine 6-E
18
SC-Type Fiber-Optic Connector
Plug
Keys
Cable
Receptacle
Light into
fiber
Key slots
Figure
5, is used to connect fiber-optic module ports or transceivers with
78-18337-01