Tighten the bolts to secure the power injector to the access point. Torque bolts to 6 to 8 ft-lbs.

Connecting the Cables

This procedure explains how to connect the cables and how to ground the access point:
Connect the two short coax cables to the power injector and to the access point.
Step 1
Caution
Step 2
Find the building's grounding electrode system and then connect the access point ground lug to it using
6 AWG copper wire. Use a crimping tool to crimp the wire to the ground lug. For more information about
attaching the ground lug to the access point, see
to the Access Point" section on page
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Note

Rooftop or Wall Mount

The mounting kit has a rooftop mounting bracket that is suitable for flat roofs, sloping roofs, and outdoor
walls. Mounting the access point on a rooftop or wall includes the following subtasks:
1.
2.
This warning applies to outdoor installations.
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
78-17634-01
Two short sub-mini RG-59 coax cables (12 in.)
To prevent damage to the access point or power injector, connect all coax cables from the
power injector to the access point and connect the power jack to the power injector before
applying power.
The grounding block and grounding wire are not required when mounting both the access point
and the antenna in a sheltered indoor environment.
Mounting the access point
Routing the cables
Cisco Aironet 1300 Series Lightweight Outdoor Access Point Mounting Instructions
Step 3
and
Step 4
28. See
Figure 11
for the ground lug location.
Mounting the Access Point
in the
"Attaching the Housing Bracket
15