Note: The following illustration shows the installation with optical receivers and
transmitters removed to provide a better view of the RF interface cable routing in
the fiber channel.
Insert the right-angled G-type connector of the RF cable assembly into the Input
7
connector on the FLI Module as shown in the previous illustration.
8
Install the Local Injection version of the 1x2 Redundant FCM into the RF
amplifier assembly in the node housing base.
Note: To remove the existing FCM, pull up carefully on its integrated handle
until it separates from the RF amplifier assembly.
9
Replace the two existing FWD I/S pads (located directly above the FCM on the
RF amplifier assembly) with 1.5 dB pads.
10 Close the node housing. Refer to Closing the Housing for complete instructions.
11 Connect the external RF source to port F2 on the node housing lid.
4019330 Rev C
CAUTION:
Be careful not to damage any existing transmitter or receiver fibers or fiber
connectors when routing the RF cable.
FLI Module Installation