- ページ 4
コントロールユニット Digitrax DS74のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Digitrax DS74 8 ページ。 Complete train control
4.0 Other DS74 Options: OPSW changes
The DS74 configuration and behavior can be configured using 40 OPSW's. The
Factory default OPSW settings will configure most common requirements.
1.
Press and hold the OPS button for about 3 seconds until the green ID and
RTS LEDs blink alternately. Release the OPS button. The DS74 is now
setup to configure OPSW 1 to 40 by sending the required SW# as Closed or
Thrown to setup an option.
2.
Send a SW# in range 1-40 as Closed/Thrown matching the wanted settings
from OPSW Table 1 choices below.
3.
When finished press and hold OPS button for 3 seconds to exit OPSW setup
mode. The DS74 will now restart with the new OPSW settings.
Factory default OPSW settings are shown in BOLD.
4.
5.
OPSW's not in this table are reserved and should be kept at Factory default T
settings for predictable operation.
6.
OPSW40 =C will reset to Factory defaults on OPSW mode exit
Table 1: DS74 Opsw setting table
OPSW#
1,2,3,4
6
10
11
14
15
16
40
© 2021 Digitrax, Inc.
Action
T,T,T,T
Pulse Solenoid mode (4 out)
C,T,T,T
Slow motion mode (4 out)
C,T,C,T
Light mode (8 out)
T
C =Disable internal Routes
T
C= Ignore standard SW com-
mands ("Bushby bit")
T
C= 8 input lines trigger
Routes
T
C= DCC SW commands only.
Ignore LocoNet SW#'s
T
C= Do not echo Route SW's
to Loconet.
T
C= Use Capacitive Discharge
in Pulse solenoid mode
T
C= Factory Reset
— 4 —
: