- ページ 22

ネットワーク・ハードウェア Cisco Universal Broadband Router Cisco uBR10012のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Cisco Universal Broadband Router Cisco uBR10012 28 ページ。 Ac power entry module for the universal broadband router
Cisco Universal Broadband Router Cisco uBR10012 にも: クイック・リファレンス・マニュアル (38 ページ)

Cisco Universal Broadband Router Cisco uBR10012 マニュアル
Removing and Replacing an AC PEM
Figure 12
CIS CO
100 00
AL AR MS
AL AR MS
Position the second replacement AC PEM in the power bay and push it forward. Verify that it goes all
Step 8
the way in and makes a secure connection with the backplane. Tighten the captive screws to secure the
unit to the chassis
Although one AC PEM can supply sufficient power for a fully configured chassis, run the
Caution
Cisco uBR10012 router with two AC PEMs installed, because this provides redundant power support.
Step 9
Plug the AC-input power cable into the power receptacle on the front panel of each AC PEM.
Step 10
Route the power cable up the front of the AC PEM and clip it into the two plastic retaining clips attached
to the surface of the PEM. Route the power cable out through the right side, so that it fits through the
notch on the right side of the front bezel cover.
AC Power Entry Module for the Cisco uBR10012 Universal Broadband Router
22
Installing the AC PEM
P O W E R
CIS CO
F A U L T
100 00
P O W E R
F A U L T
(Figure
12).
(Figure
13)
OL-24536-01