- ページ 39

サーバー Cisco Firepower 1120のPDF ハードウェア・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。Cisco Firepower 1120 42 ページ。 Connected grid router
Cisco Firepower 1120 にも: ハードウェア・インストール・マニュアル (30 ページ), インストレーション・マニュアル (6 ページ), クイック・スタート・マニュアル (10 ページ), マニュアル (6 ページ), 配備マニュアル (8 ページ), はじめに (42 ページ), ハードウェア・インストール・マニュアル (42 ページ)

Cisco Firepower 1120 ハードウェア・インストール・マニュアル
Installation, Maintenance, and Upgrade
Note
Step 1
Copy the serial number and store in a secure place. To find the serial number, see
Step 2
Perform the Step 1 as described in
Step 3
Install the cable management brackets.
Figure 27: Install the Cable Management Screws into the Rack-Mount Bracket
Step 4
Connect the cables to the ports. Make sure that the cables have enough slack to route them through the cable mounting
brackets.
If you are installing the FIPS opacity shield after the initial product installation, the cables are connected. If
Note
the attached cables do not have enough slack to route them through the cable mounting brackets (as shown
in the figure below), you will have to turn the power off on the appliance, remove the cables, route the cables
through the cable mounting brackets, reattach the cables, and continue with Step 5 below.
When you toggle the power switch from ON to OFF, it takes several seconds for the system to power down.
Note
Do not remove the power cable until the power LED is off. After removing power from the chassis either by
moving the power switch to OFF or unplugging the power cord, wait at least 10 seconds before turning power
back ON.
• One FIPS opacity shield (part number 69-100612-01)
• Two cable management brackets (part number 700-117013-01)
• Eight Phillips 8-32 x 0.375-inch screws (part number 48-0629-01) used to attach the FIPS opacity
shield to the cable management brackets
• Ten Tamper Evidence Labels (TEL) (part number 47-25553-01)
The TELs are made of a special thin gauge vinyl with self-adhesive backing.
Once the CO attaches them on the chassis, any attempt to open the chassis damages
the TELs or the chassis cover. Because the TELs have nonrepeated serial numbers,
the CO can inspect them for damage and compare them against the applied serial
numbers to verify whether the chassis has been tampered with. TELs with curled
corners, rips, and slices indicate tampering. The word "FIPS" or "OPEN" may
appear if the label has been peeled back.
Rack-Mount the Chassis, on page
Install the FIPS Opacity Shield in a Two-Post Rack
Serial Number
25.
Cisco Firepower 1100 Series Hardware Installation Guide
Location.
35