Physical and Environmental Parameters
Parameter
Form Factor
Dimensions (D x W x H)
Max Weight
Power Supply
Operating Temperature
Non-Operating Temperature
Non-Operating Humidity
Acoustic Noise
Operating Shock
Package Shock
Air Flow
ESD
System Cooling Requirements
Regulatory Conformance
This Sourcefire Defense Center conforms to multiple national and international standards. For a full list of regulatory compliance, see the
Sourcefire 3D System Installation Guide .
Security Considerations
Before you install your Defense Center, Sourcefire recommends that you consider the following:
Locate your Defense Center in a lockable rack within a secure location that prevents access by unauthorized personnel.
Allow only trained and qualified personnel to install, replace, administer, or service the Defense Center.
Always connect the management interface to a secure internal management network that is protected from unauthorized access.
Quick Start Guide - DC750
LEDs, SPECIFICATIONS, REGULATORY, and SECURITY
A USB port
B Power button
C System status LED
D Power LED
E Fixed disk drive status LED
F NIC 1 activity status LED
G NIC 2 activity status LED
Color Indications
A green light indicates that the system is operating normally.
A blinking green light indicates that the system is operating in a degraded condition.
DC750 (Rev 1) only: A blinking amber light indicates that the system is in a non-critical error condition.
DC750 (Rev 1) only: An amber light indicates that the system is in a critical or non-recoverable error condition.
No light indicates POST/system stop.
IMPORTANT! - DC750 (Rev 1) only
Amber status light takes precedence over green. When amber is on or blinking, green is off.
A green light indicates there is power.
A blinking green light indicates the system is sleeping.
No light indicates there is no power.
A blinking green light indicates that the fixed disk drive is active.
DC750 (Rev 1) only: An amber light indicates there is a fixed disk drive fault.
No light indicates either there is no drive activity, or the system is powered off or sleeping.
A blinking green light indicates there is activity.
No light indicates there is no activity.
Description
Indicates whether the link is up. If the LED is on, the link is up; if the LED is off, there is no link.
Indicates activity on the port. A blinking LED indicates activity; if the LED is off, there is no activity.
DC750 (Rev 1)
1U
20.0" x 16.93" x 1.67" (50.8 cm x 43.0 cm x 4.24 cm)
33 lbs (15 kg)
350 W power supply at 120 VAC
9.5 Ampere max. at 110 Volts, 50/60 Hz
4.75 Ampere max. at 220 volts, 50/60 Hz
50°F to 95°F (10°C to 35°C) with the maximum rate of change
not to exceed 18°F (10°C)
-40°F to +158°F (-40°C to +70°C)
90%, non-condensing at 95°F (35°C)
<7.0 dBA (rack mount) in an idle state at typical office ambient
temperature
No errors with half a sine wave shock of 2G (with 11
millisecond duration)
Operational after 24" (61 cm) free fall; cosmetic damage may
be present (chassis weight: 40-80 lbs / 18-36 kg)
Front to back
+/- 12kV for air discharge and 8 K for contact
1660 BTU/hour
DC750 (Rev 2)
DC750 (Rev 2)
1U
21.8" x 17.25" x 1.67" (55.37 cm x 43.82 cm x 4.24 cm)
33 lbs (15 kg)
250 W power supply at 120 VAC
6.0 Ampere max. at 110 Volts, 50/60 Hz
3.0 Ampere max. at 220 volts, 50/60 Hz
50°F to 95°F (10°C to 35°C) with the maximum rate of change
not to exceed 18°F (10°C)
-40°F to +158°F (-40°C to +70°C)
90%, non-condensing at 82.4°F (28°C)
<7.0 dBA (rack mount) in an idle state at typical office ambient
temperature
No errors with half a sine wave shock of 2G (with 11
millisecond duration)
Operational after 24" (61 cm) free fall; cosmetic damage may
be present (chassis weight: 40-80 lbs / 18-36 kg)
Front to back
+/- 12kV for air discharge and 8 K for contact
1660 BTU/hour
Page 4 of 4
A ID button with ID LED
B Non-maskable interrupt button
C NIC activity status LEDs
D Reset button
E Fixed disk drive status LED
F Power button with power LED
G System status LED
2014-5.3-2