Cisco Sourcefire Defense Center 750 Посібник із швидкого старту - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник із швидкого старту для Сервер Cisco Sourcefire Defense Center 750. Cisco Sourcefire Defense Center 750 4 сторінки. Network management device
Також для Cisco Sourcefire Defense Center 750: Посібник для початківців (31 сторінок)
DC750
LEDs
Front Panel and Front Panel LEDs
DC750 (Rev 1)
LED
System status
Power
Hard Drive Activity
NIC Activity
Management Interface LEDs
LED
Left (Link)
Right (Activity)
Hardware Specifications
Physical and Environmental Parameters
Parameter
Form Factor
Dimensions (D x W x H)
Max Weight
Power Supply
Operating Temperature
Non-Operating Temperature
Non-Operating Humidity
Acoustic Noise
Operating Shock
Package Shock
Air Flow
ESD
System Cooling Requirements
Regulatory Conformance
This Sourcefire Defense Center conforms to multiple national and international standards. For a full list of regulatory compliance, see the
Sourcefire 3D System Installation Guide .
Security Considerations
Before you install your Defense Center, Sourcefire recommends that you consider the following:
•
Locate your Defense Center in a lockable rack within a secure location that prevents access by unauthorized personnel.
•
Allow only trained and qualified personnel to install, replace, administer, or service the Defense Center.
•
Always connect the management interface to a secure internal management network that is protected from unauthorized access.
Quick Start Guide - DC750
LEDs, SPECIFICATIONS, REGULATORY, and SECURITY
A USB port
B Power button
C System status LED
D Power LED
E Fixed disk drive status LED
F NIC 1 activity status LED
G NIC 2 activity status LED
Color Indications
A green light indicates that the system is operating normally.
A blinking green light indicates that the system is operating in a degraded condition.
DC750 (Rev 1) only: A blinking amber light indicates that the system is in a non-critical error condition.
DC750 (Rev 1) only: An amber light indicates that the system is in a critical or non-recoverable error condition.
No light indicates POST/system stop.
IMPORTANT! - DC750 (Rev 1) only
Amber status light takes precedence over green. When amber is on or blinking, green is off.
A green light indicates there is power.
A blinking green light indicates the system is sleeping.
No light indicates there is no power.
A blinking green light indicates that the fixed disk drive is active.
DC750 (Rev 1) only: An amber light indicates there is a fixed disk drive fault.
No light indicates either there is no drive activity, or the system is powered off or sleeping.
A blinking green light indicates there is activity.
No light indicates there is no activity.
Description
Indicates whether the link is up. If the LED is on, the link is up; if the LED is off, there is no link.
Indicates activity on the port. A blinking LED indicates activity; if the LED is off, there is no activity.
DC750 (Rev 1)
1U
20.0" x 16.93" x 1.67" (50.8 cm x 43.0 cm x 4.24 cm)
33 lbs (15 kg)
350 W power supply at 120 VAC
9.5 Ampere max. at 110 Volts, 50/60 Hz
4.75 Ampere max. at 220 volts, 50/60 Hz
50°F to 95°F (10°C to 35°C) with the maximum rate of change
not to exceed 18°F (10°C)
-40°F to +158°F (-40°C to +70°C)
90%, non-condensing at 95°F (35°C)
<7.0 dBA (rack mount) in an idle state at typical office ambient
temperature
No errors with half a sine wave shock of 2G (with 11
millisecond duration)
Operational after 24" (61 cm) free fall; cosmetic damage may
be present (chassis weight: 40-80 lbs / 18-36 kg)
Front to back
+/- 12kV for air discharge and 8 K for contact
1660 BTU/hour
DC750 (Rev 2)
DC750 (Rev 2)
1U
21.8" x 17.25" x 1.67" (55.37 cm x 43.82 cm x 4.24 cm)
33 lbs (15 kg)
250 W power supply at 120 VAC
6.0 Ampere max. at 110 Volts, 50/60 Hz
3.0 Ampere max. at 220 volts, 50/60 Hz
50°F to 95°F (10°C to 35°C) with the maximum rate of change
not to exceed 18°F (10°C)
-40°F to +158°F (-40°C to +70°C)
90%, non-condensing at 82.4°F (28°C)
<7.0 dBA (rack mount) in an idle state at typical office ambient
temperature
No errors with half a sine wave shock of 2G (with 11
millisecond duration)
Operational after 24" (61 cm) free fall; cosmetic damage may
be present (chassis weight: 40-80 lbs / 18-36 kg)
Front to back
+/- 12kV for air discharge and 8 K for contact
1660 BTU/hour
Page 4 of 4
A ID button with ID LED
B Non-maskable interrupt button
C NIC activity status LEDs
D Reset button
E Fixed disk drive status LED
F Power button with power LED
G System status LED
2014-5.3-2