- ページ 7
ドア開閉システム Digiway SL500-LVのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Digiway SL500-LV 9 ページ。 Sliding gate motor drive
9. Manual release
A: What to do during a power failure (battery run out) or faulty:
If got battery back, then take the red cap off or take whole cover off, using the 8mm Allen key, insert to
the release bolts holes or use hand, clockwise turn the bolts several turns, then can manually push gate
open.
Re-engage the motor, turn the manually release bolts several turns, manually move gate, gate will
engage.
Reset power (initialization), remove the 6 pins plug (AC power, battery and motor), wait about 20
seconds, then plug it back. Use remote or push button operate the gate, controller will automatic
reprogrammed.
7