- ページ 7
サーモスタット DIHS Optima W R2 PlusのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。DIHS Optima W R2 Plus 7 ページ。
Step 3: Clip the front of the thermostat onto the back plate.
TC-25 TC-30:
Step 1: Using a small screwdriver, slightly loosen receiver cover plate.
Step 2: Terminate the thermostat as shown in the diagram
Step 3: Clip the front of the thermostat onto the back plate.
Types of receivers (with RF and WiFi);
TC-25: Wall mounted receiver, 230Vac, voltfree output, 10 A Ohmic load / 4A Cap/ind load.
TC-30: Wall mounted receiver with floorsensor, 230Vac, voltfree output, 10 A Ohmic load / 4A Cap/ind
Load.
TC-35: Flush mounted receiver, 230Vac, voltfree output, 16 A Ohmic load / 10A Cap/ind load.
TC-40: Flush mounted receiver with floorsensor, 230Vac, voltfree output, 16 A Ohmic load / 10A
Cap/ind Load.
TC-60: Plugin mounted receiver, 230Vac, powered output, 16 A Ohmic load / 10A Cap/ind load.
NOTE;
When the voltage output is above 230Vac, eg 240-250Vac, then the capacity of the receiver should be
lower. For the TC-25 and TC-30 the maximum ohmic load is then 6A. For the TC-35, TC-40 and TC-60
its 12A ohmic load.
OPTIMA W R2 PLUS THERMOSTAT
Optima W PLUS is a development of DIHS BV, NETHERLANDS. www.dihsbv.nl