If no action has been performed on the keypad and the panel is in the DISARMED mode,
the panel LCD screen will show as following:
DIS
ARMED
LOG
Figure5 : LCD display when disarmed
: it means that the panel has been set to sounder alarm
: It means there are 85 items of information (including alarm information,
85
Armed / disarmed information and others).
10
8
: It means the date: November 8th.
M
D
18
52
: It means the time: 18:52
H
M
2
: It Means weekday Tuesday.
D
Timed
: It means timed auto arming/disarming has been programmed
: It means there are 2 items of alarms which have not been viewed. After
02
Viewing the information, the display 02 will disappear.
1
: It means that the No. 1 zone armed within 8 zones from No.1 to No.1 8
2.2.2 When the panel is set in the away armed mode,the LCD screen will show the following :
ARMED
LOG
Figure 6: LCD display when part armed
The meaning of the characters as follows:
83:Means there are 83 items of information (including alarm information, Armed/Disarmed
information and others).
1234 78 : Means that Zone No. 1, 2, 3, 4,7and 8 zones are armed.
Zones 5 & 6 are Un-Armed as there are no sensors in the two zones
2.2.3 When there is an alarm, the panel LCD will show as following:
5
M
D
H
M
D
TIMED
M
D
H
M
D
After entering correct PIN code the panel will follow the instructions given using the
DTMF tones from the keypad of the remote phone.
Press 1 to tell the panel to switch to listen in mode
Press 2 to tell the panel to switch to speak mode
Press 3 to tell the panel to switch its sounder ON
Press 4 to tell the panel to switch listening in OFF
Press 5 to tell the panel to terminate the call, disengage the phone line
Press 6 to tell the panel to switch its sounder OFF
Press 7 to tell the panel to ARM
Press 8 to tell the panel to DIS ARM
4.9 Listen in and speak through key fob
When the phone connected to the panel is call ed ,and the phone rings , press a single
key on the Key Fob directly , then the user could Listen in the premise and speak to the
occupants.
4.10 Alarm confirming
When the panel reports an alarm event to the C.S.it does so by using Ademco contact
Zone.
ID protocol, sometimes called ADEMCO fast format. After the data is transferred to the
C.S. the operator then has access to the customer details, address, name, phone numbers,
key holders etc. He also has audio access to the premises. He can Listen-in or Speak to the
occupants, this will allow the C.S. operator to request a pre-arranged password to confirm
the identity of the person he is speaking to or make a challenge to an unindented occupant.
The C.S. operator will take the appropriate action determined by the circumstances at the
time.
The C.S. Pry 1 and Pry 2 phone numbers are located in fields 1 and 2 and the account
code is located in field 7 in the PHONE program and configuration. In addition to above
procedure the panel has the ability to report alarm incidents to up to 4 private telephone
numbers. These dedicated numbers must be programmed into fields 3 to 6 of the PHONE
program and configuration. These numbers are referred to as USER numbers.
After reporting an alarm event to the C.S., once the C.S. has terminated the call the
panel Can be programmed to call the USER numbers in sequence, i.e No3 field First, then
4 etc.
When the panel dials the user phone number and the user answers the telephone,
there will be a beep sound from the panel showing that the phone is being answered. The
user then presses the * key on USER hand set to confirm the alarm, on doing so the panel
will allow the USER to listen-in the premises.