- ページ 13

モニター MSI MSI-8000HDのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。MSI MSI-8000HD 48 ページ。 Rf remote display

MSI MSI-8000HD 取扱説明書
2.0

Operation

2.1 Power

To turn on the power.
1. Press
POWER
version number will display.
The MSI-8000HD is ready for use.

2.2 Zero

Sets the zero reading of the Scale/Dyna-Link. Takes out small deviations in zero when
the Scale/Dyna-Link is unloaded. (See Section 2.3 for zeroing (Taring) package,
rigging or pallet weights)
1. Press
ZERO
zero function to work.
MSI-8000HD
The
Zero - Rules for Use:
• Works in GROSS or NET mode.
• Zeroing while in Net mode will zero the gross load causing the display to show
the negative Tare value.
• The Scale/Dyna-Link must be stable within the motion window. They will not
zero until the stable annunciator is on. The Scale/Dyna-Link will "remember"
that it has a zero request for two seconds. If motion clears in that time, they will
zero.
• The Scale/Dyna-Link will accept a zero setting over the full Range of the Scale/
Dyna-Link. Zero settings above 4% of full Scale/Dyna-Link will subtract from
the overall capacity of the Scale/Dyna-Link.
Example
If 100 lb is zeroed on a 1000 lb Scale/Dyna-Link, the overall capacity of the
Scale/Dyna-Link will reduce to 900 lb plus the allowed over-range amount.
, the LCD will show all segments for a display text and the software
. The load reading must be stable within the motion window for
stores the zero reading, and can restore it even if power fails.
Operation
9