Aeon Labs Home Energy Meter
(Z-Wave Home Energy Meter)
Introduction:
The Aeon Labs Home Energy Meter is energy meter for the
entire home. It can wirelessly report immediate wattage
and kWh usage of the AC mains to a Z-Wave gateway.
By taking advantage of the Z-Wave mesh network,
commands can be routed to their destination via
intermediary "listening" Z-Wave products. Products that
are Z-Wave certified can be used and communicate with
other Z-Wave certified devices.
Z-Wave Network Instructions:
The Aeon Labs Home Energy Meter must be paired
(included) into a Z-Wave network before it can receive Z-
Wave commands to report its energy usage. The home
energy meter can only communicate to devices within it's
own z-wave network.
Note: If the Home Energy Meter is not currently paired into
a Z-Wave network, the LED on the Home Energy Meter will
blink after pressing the button located near the batteries.
- 1 -
Adding/Including/Pairing the Home Energy Meter
•
into a Z-Wave Network
1.
Press the button on the Aeon Labs Z-Stick to begin the
Z-Wave inclusion process.
OR
Press the button labeled "Include" on the Aeon Labs
Minimote to begin the Z-Wave inclusion process.
Note: To include the Aeon Labs Home Energy Meter
with other controllers, please consult the operation
manual for these controllers on how to include Z-
Wave products into an existing network.
instructions on select partner gateways, visit
www.aeon-labs.com/support.
2.
After placing 4 AA batteries into the Home Energy
Meter, press the button located near the batteries .
Troubleshooting: If the Aeon Labs Home Energy Meter was
not successfully included into any Z-Wave network, the LED
will blink after pressing the button near the batteries. If the
Aeon Labs Home Energy Meter was successfully included to
a Z-Wave network, the LED will be lit solid after pressing the
button.
- 2 -
Removing/Excluding/Resetting the Home Energy
•
Meter from your Z-Wave Network
1.
Hold the button on the Aeon Labs Z-Stick to begin the
Z-Wave removal process.
OR
Press the button labeled "Remove" on the Aeon Labs
Minimote Stick to begin the Z-Wave removal process.
Note: To include the Aeon Labs Home Energy Meter
with other controllers, please consult the operation
manual for these controllers on how to include Z-
Wave products into an existing network.
instructions on select partner gateways, visit
For
www.aeon-labs.com/support.
2.
After placing 4 AA batteries into the Home Energy
Meter, press the button located near the batteries .
Troubleshooting: If the Aeon Labs Home Energy Meter was
removed from the Z-Wave network, the LED will blink after
pressing the button near the batteries. If the Aeon Labs
Home Energy Meter was not successfully removed from a
Z-Wave network, the LED will be lit solid after pressing the
button.
- 3 -
Power by an USB/AC Adapter
•
While the Aeon Labs Home Energy Meter can operate for
nearly a year on batteries, it can also be powered through
it's USB port. While powered by the USB port, the Home
Energy Meter can track kWh energy usage and report
wattage every few seconds.
AC Mains Installation
•
IMPORTANT: It is recommened that a licensed electrician
assist with the installation as you must open the main
circuit box (usually located outside of your house).
After opening the main circuit box panel, clip each of the
clamps of the Aeon Labs Home Energy Meter around the
For
two incoming wires that connect to the main circuit breaker
from the main wire going into the box.
If you have purchased the optional Home Energy Meter AC
Adapter, you may insert one of the AC adapters exposed
wires into one of the neutral bus terminals and the other
exposed wire into the live terminals coming from the main
circuit breaker.
Note: Some AC Mains boxes are made of metal and may
reduce the radio communication power from the Home
Energy Meter to other Z-Wave devices within the house. To
improve radio performance, the Home Energy Meter may
be placed outside of the main circuit box. The Home Energy
Meter is IP43 weatherized to be resistant to rain and snow
when placed vertically with the wires protruding from the
bottom of the unit.