- ページ 15

ホブ Ariston NIV 320BのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Ariston NIV 320B 17 ページ。
Ariston NIV 320B にも: 取扱説明書 (20 ページ)

Ariston NIV 320B 取扱説明書
TROUBLESHOOTING GUIDE
-
Read and follow the instructions given in the section "SAFETY INSTRUCTIONS".
-
Make sure there is not a power outage.
-
Dry the hob thoroughly after cleaning it.
-
If, when the hob is switched on, alphanumeric codes appear on the display, consult the
following table for instructions.
-
If the hob cannot be switched off after using it, disconnect it from the power supply.
If there is an error, error code will be showed at the heater displays.
ERROR CODE
E1
Cooling Fan is disabled
E3
Supply voltage is over than rated
values
E4
Supply frequency is different from
rated values
E5
Hob inside temperature is too high
E6
Communication error between
touch control and heater
E7
Coil temperature sensor is disabled
E8
Cooler temperature sensor is
disabled
E9
Calibration error
POSSIBLE CAUSES
ERROR ELIMINATION
Contact Whirlpool After Sale Service
Turn the hob off, wait until"H"disappears for all
zones and then turn the hob on. If same error is
appeared again, contact Whirlpool After Sale
Service
Turn the hob off, wait until"H"disappears for all
zones and then turn the hob on. If same error is
appeared again, disconnect the hob from the
mains supply and connect it again. If same error is
still appeared, contact Whirlpool After Sale
Service
Turn the hob off and wait for hob to cool down.
Contact Whirlpool After Sale Service
15