- ページ 6

ドライヤー Whirlpool 8527813のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Whirlpool 8527813 13 ページ。 Commercial stacked dryer gas & electric

Now Start...
With dryer in laundry area.
WARNING
Excessive Weight Hazard
Use two or more people to move
and install dryer.
Failure to do so can result in
back or other injury.
1.
Put on safety glasses and gloves.
Check that each leg is approximately
1 inch (2.5 cm) from base.
2.
Wipe the interior of the drums
thoroughly with a damp cloth.
3.
Install coin vaults and locks (not
supplied) into meter case openings.
4.
Install control panel lock and
key (not supplied).
5.
If you wish to change the 45-
minute dryer timing cams to either 30-
or 60-minute timing cams, see "To
change to a 30- or 60-minute timing
cam," Page 3. Complete all of the
steps given in that section before
going to Step 6.
6.
Open control panel and rest it
on the bottom edge of the opening.
Attach slide extension (with flange
pointing down) to one of the coin-
slide mechanisms. Insert the coin-slide
mechanism through the opening to
left of the control panel.
Page 6
7.
Secure coin slide mechanism
from inside the control panel using
the 3/16" bolt and washer included
with the slide mechanism. Install coin
box.
8.
Repeat Steps 6 and 7 for the
other coin slide mechanism. Close
control panel.
9.
Remove red caps from gas
pipes. Carefully move dryer into final
position. Place level on top of the
dryers or collar, first side to side; then
front to back. If the dryers are not
level, adjust the legs up or down until
level.
10.
Connect gas supplies to
dryers. Use pipe-joint compound
resistant to the action of L.P. gas for
gas connections. If flexible metal
tubing is used, be certain there are
no kinks.
11.
Open the shutoff valve in the
gas supply line.
12.
Use a non-corrosive leak
detection fluid to check for leaks.
Bubbles around connections will
indicate a leak. If a leak appears,
shut off gas valve controls and adjust
connections. Then check
connections again. All connections
must be wrench-tightened.
13.
To exhaust dryer, see
"Exhaust requirements," Pages 3-4.
Connect exhaust vent system to dryer
exhaust outlet and exhaust hood
using 4" (10.2 cm) clamps. Use
caulking to seal exterior wall opening
around exhaust hood.
14.
Carefully move dryer into
final position. Place level on top of
the dryer, first side to side; then front
to back. If the dryer is not level, adjust
the legs of the dryer up or down until
the dryer is level.
15.
Plug power supply cord into
grounded outlet.
16.
Check dryer operation (some
accumulated time may be on the
timer due to factory testing).
Insert coins in slide and press slide in
slowly. (Operating time will
accumulate per number of coins and
type of timing cam used.) Push
START/RESTART button. Using a full
heat cycle (not the air cycle), let the
dryer run for at least five minutes.
Dryer will stop when time is used up.
Note: Dryer door must be closed for
dryer to operate. When door is open,
dryer stops, but timer continues to run.
To restart dryer, close door and push
START/RESTART button.
17.
If the burner does not ignite
and you can feel no heat inside the
dryer, shut off dryer for five minutes.
Check that all supply valve controls
are in "ON" position and that the
electrical cord is plugged in. Repeat
five-minute test.
18.
If drying time is too long,
make sure lint screen is clean.