Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of vent and
catch lint. Do not use duct tape.
Exhaust:
Recommended hood styles.
B
A
4"
(102 mm)
4"
(102 mm)
A. Louvered hood style
B. Box hood style
C. Angled hood style is acceptable
An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
flowers, rocks or bushes, snow line, etc.).
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and lint to collect
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
Housecleaning problems and health problems.

Plan Vent System

Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
A
A. Dryer
F. Rigid metal or flexible metal vent
B. Elbow
G. Vent length necessary to connect elbows
C. Wall
H. Exhaust outlet
D. Exhaust hood
E. Clamps
12
Clamp
Acceptable hood style.
C
4"
(102 mm)
B
C
D
E
F
G
B
I
H
I. Optional side exhaust outlet
optional exhaust installations:
This dryer can be converted to exhaust out the right side, left
side, or through the bottom. If you prefer, you may contact your
local dealer to have the dryer converted.
Cover unused exhaust holes with the following kit:
279818 (white)
Contact your local dealer.
2
½"
(64 mm)
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
A
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
noTE: The following kits for close clearance alternate
installations are available for purchase. Please see the
"Assistance or Service" section of the Dryer User Instructions.
Over-the-Top Installation:
Part Number 4396028
WARNING
Fire Hazard
B
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
A
A. Over-the-top installation (also available
with one offset elbow)
B. Periscope installation