ELECTRIC DRYER ELECTRICAL CONNECTIONS
Connection Options
Power Cord
4-wire receptacle (NEMA Type 14-30R)
Go to "Power Supply Cord Connection" section.
3-wire receptacle (NEMA Type 10-30R)
Go to "Power Supply Cord Connection" section.
NOTE: If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to "Connecting 3-Wire
Connection: Optional" section. This connection may be used with either a power supply cord or a direct wire connection.
Power Supply Cord Connection
Remove Terminal Block Cover
Remove hold-down screw and terminal block cover.
18
(FOR U.S.A. ONLY)
Direct Wire
4-wire direct
Go to "Direct Wire Connection" section.
3-wire direct
Go to "Direct Wire Connection" section.
Power Supply Cord Strain Relief
1. Insert strain relief.
Remove the screws from a ¾" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening
(B) so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
2. Insert power cord into strain relief.
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
A
B
C
D