- ページ 32

アンプ Yamaha AG-StompのPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。Yamaha AG-Stomp 45 ページ。 Yamaha accoustic guitar/pre-amplifier owner's manual
Yamaha AG-Stomp にも: オーナーズマニュアル (32 ページ), パッチリスト (1 ページ), (オランダ語)マニュアル (32 ページ)

Yamaha AG-Stomp サービスマニュアル
AG-Stomp

ERROR MESSAGES

If an error occurs during operation, one of the following error message numbers will appear in the display.
Stop operation of the AG-Stomp and follow one of the solutions described below.
E1
: MIDI Receive Buffer Full
CAUSE:
SOLUTION: Try reducing the amount of data being sent, or break the data into smaller blocks.
E2
: Communication Error.
CAUSE:
SOLUTION: Check all connections, etc. and try again.
E3
: Bulk Receive Check Sum Error.
CAUSE:
SOLUTION: Check all connections and transmitted data, and try again.
E4
: Bulk Receive Data Abnormality.
CAUSE:
SOLUTION: Check all connections and transmitted data, and try again.
32
Too much MIDI data is being received and the buffer is full
An abnormality is detected during MIDI communications.
The check sum does not match the received MIDI bulk dump data.
An abnormality is detected while receiving the bulk dump.