- ページ 8

電動工具 Clarke CSA10FのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Clarke CSA10F 11 ページ。 10 ton hydraulic press

MAINTENANCE

A Visual inspection must be made before each use of the press, checking for
leaking hydraulic fluid, and damaged, loose or missing parts.
Owners and/or users should be aware that repair of this equipment may require
specialised knowledge and facilities. It is recommended that a thorough annual
inspection of the press be made and that any defective parts, decals or warning
labels be replaced with genuine Clarke parts.
Any press which appears to be damaged in any way, is found to be badly worn,
or operates abnormally SHOULD BE REMOVED FROM SERVICE until necessary repairs
are made.
Periodically check the press frame to make sure all bolts are tight and inspect
for cracked welds, bent, loose or missing parts.
Periodically check the hydraulic connections for possible leaks. Replace or
properly repair damaged or leaking hydraulic components before using.
Periodically apply a light smear of oil to the moving parts and the bed support
pins.
If oil leaks, caused by a loose union/connection etc., have been repaired,
check the hydraulic pump oil level, by removing the pump from its mounting,
holding it vertically on its nose, and removing the filler/dipstick, shown at 'A',
Fig.1. Top up if necessary to the level on the dipstick, with CLARKE Hydraulic
Oil, Part No. 3050830 only.
This operation is carried out with the ram fully retracted.
Replace the Hydraulic oil every TWO years. This operation requires the
dismantling of the hydraulic system, for which you should consult your CLARKE
dealer.
8